Quick
Acting Automatic "3 and 2 Way" Valves
for the Bypass System of High Pressure Preheaters
VALVES
HOME PAGE
|
Auto
Bypass Valves
|
|
|
|
This
two valve system has been designed to prevent risks in case
of failure of High Pressure Preheaters.
It consists of one 3 way valve and one 2 way valve having both
an internal piston connected to the stem and sliding into a
cylindrical chamber. In case of heater tube bundle failure,
a level switch sensing the water level in the Preheater shell
will open the exhaust valves generating differential pressure
between the two parts of the cylindrical chamber. This pressure
difference actuates the stem movement, operating the valves
and deviating the flow, therefore bypassing the Preheater.
Operating speed can be controlled by an external regulating
valve. All this system does not need any external power (i.e.
electrical or pnaumatical) so giving best protection in case
of accident.
We produce this system according to rating ASME 900, 1500, 2500
and Special Classes in size up to DN 18".
|